QD-PCS-A125_A4-G

PCS Quad In-Band Diplexer GB125, A/ADBEFCG Bands with AISG/DC Sense

  • Automatic dc switching with dc sense
Product Classification  
Product Type   Diplexer
   
Electrical Specifications Rx (Uplink)  
Frequency Band   1850.625 – 1855.625 MHz
Insertion Loss, maximum   1.00 dB
Insertion Loss, typical   0.80 dB
Isolation, minimum   28 dB
Isolation, minimum, specific   20 dB (±500 KHz from band edge)
Return Loss, minimum   18 dB
   
Electrical Specifications Tx (Downlink)  
Frequency Band   1930.625 – 1935.625 MHz
Input Power, PEP, maximum   3000 W
Insertion Loss, maximum   1.00 dB
Insertion Loss, typical   0.80 dB
Isolation, minimum   28 dB
Isolation, minimum, specific   20 dB (±500 KHz from band edge)
Return Loss, minimum   18 dB
Total Group Delay, maximum   230 ns
   
Electrical Specifications 2 Rx (Uplink)  
Frequency Band   1856.875 – 1914.75 MHz
Insertion Loss, maximum   1.00 dB
Insertion Loss, typical   0.80 dB
Isolation, minimum   28 dB
Isolation, minimum, specific   20 dB (±500 KHz from band edge)
Return Loss, minimum   18 dB
   
Electrical Specifications 2 Tx (Downlink)  
Frequency Band   1936.875 – 1994.75 MHz
Input Power, PEP, maximum   3000 W
Insertion Loss, maximum   1.00 dB
Insertion Loss, typical   0.80 dB
Isolation, minimum   28 dB
Isolation, minimum, specific   20 dB (±500 KHz from band edge)
Return Loss, minimum   18 dB
Total Group Delay, maximum   230 ns
   
AISG Electrical Specifications  
AISG Carrier   2176 KHz ± 100 ppm
Insertion Loss, maximum   1.00 dB
Return Loss, minimum   15 dB
   
Electrical Specifications  
3rd Order IMD Test Method   Two +43 dBm carriers
3rd Order IMD, maximum   153 dBc
Lightning Surge Current   10 kA
Lightning Surge Current Waveform   8/20 waveform
   
Block Diagram  
Click on image below to enlarge.
   
dc/AISG Auto-Sense Logic  
Click on image below to enlarge.
   
General Specifications  
Application   Indoor   |   Outdoor
Includes   Brackets
   
Mechanical Specifications  
Connector Interface   7-16 DIN Female
Connector Interface Style   Medium neck
Ground Screw Diameter   8.00 mm
   
Environmental Specifications  
Ingress Protection Test Method   IEC 60529:2001, IP67
Operating Temperature   -40 °C to +60 °C (-40 °F to +140 °F)
   
Dimensions  
Depth   148.0 mm   |   5.8 in
Height   465.0 mm   |   18.3 in
Width   365.0 mm   |   14.4 in
Weight   28.0 kg   |   61.7 lb
   
Outline Drawing  
Click on image below to enlarge.
Add Cancel