SPX619212342T-43 | E14F20P21
Compact Twin Pentaplexer 617-960/AWS/PCS/WCS/ 3.3-4.2G, dc bypass on low ports, with 4.3-10 connectors
Features and Benefits
- New Combining Solution to introduce 5G, 3.5GHz band
- Industry leading PIM performance
- New 4.3-10 connectors for improved PIM performance and size reduction
- Suitable for feeders cables reduction
- dc/AISG pass-through on low frequency ports
- Clam shell configuration
Specifications
Product Classification
Product Type | Pentaplexer |
General Specifications
Color | Gray |
Modularity | 2-Twin |
Mounting | Pole | Wall |
Mounting Pipe Hardware | Band clamps (2) |
RF Connector Interface | 4.3-10 Female |
RF Connector Interface Body Style | Long neck |
Dimensions
Height | 147 mm | 5.787 in |
Width | 235 mm | 9.252 in |
Depth | 92 mm | 3.622 in |
Mounting Pipe Diameter Range | 43–122 mm |
Outline Drawing
Click on image to enlarge. |
Electrical Specifications
dc Pass-through | Band 1 |
Impedance | 50 ohm |
License Band, Band Pass | APT 700 | AWS 1700 | AWS 2000 | CEL 850 | CEL 900 | IMT 2100 | LMR 800 | PCS 1900 | TDD 3500 | USA 600 | USA 700 | WCS 2300 |
Electrical Specifications, Common Port
Composite Power, RMS | 500 W |
Electrical Specifications, dc Power/Alarm
dc/AISG Pass-through Method | Factory set |
dc/AISG Pass-through Path | Branch 1 |
dc/AISG Pass-through, combiner | Branch 1 |
dc/AISG Pass-through, demultiplexer | Branch 1 |
Lightning Surge Current | 5 kA |
Lightning Surge Current Waveform | 8/20 waveform |
Pass-through Current, maximum | 2 A |
Voltage | 7–30 Vdc |
Electrical Specifications, AISG
AISG Carrier | 2.176 MHz ± 100 ppm |
AISG Pass-through Current, maximum | 2 A |
Electrical Specifications
Sub-module | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 |
Branch | 1 | 2 | 3 | 4 | 5 |
Port Designation | PORT 1 617-960 | PORT 2 1850-1995 | PORT 3 AWS | PORT 4 2305-2360 | PORT 5 3300-4200 |
Electrical Specifications, Band Pass
Frequency Range, MHz | 617–960 | 1850-1995 | 1695–1780 2110–2200 | 2305–2360 | 3300–4200 |
Insertion Loss, typical, dB | 0.15 | 0.20 | 0.20 | 0.25 | 0.15 |
Return Loss, typical, dB | 21 | 20 | 20 | 20 | 20 |
Isolation, minimum, dB | 45 @ 1695–1780 2110–2200 50 @ 1850–1995 50 @ 2305–2360 50 @ 3300–4200 | 40 @ 1695–1780 50 @ 2110–2200 50 @ 2305–2360 50 @ 3300–4200 50 @ 617–960 | 40 @ 1850–1995 40 @ 2305–2360 50 @ 3300–4200 50 @ 617–960 | 45 @ 2110–2200 50 @ 1695–1780 50 @ 1850–1995 50 @ 3300–4200 50 @ 617–960 | 50 @ 1695–1780 2110–2200 50 @ 1850–1995 50 @ 2305–2360 50 @ 617–960 |
Input Power, RMS, maximum, W | 200 | 200 | 200 | 200 | 200 |
Input Power, PEP, maximum, W | 1,200 | 1,200 | 1,200 | 1,200 | 800 |
3rd Order PIM, typical, dBc | -161 | -161 | -161 | -161 | -161 |
3rd Order PIM Test Method | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones |
Block Diagram
Click on image to enlarge. |
Mechanical Specifications
Wind Speed, maximum | 240 km/h (149 mph) |
Environmental Specifications
Operating Temperature | -40 °C to +65 °C (-40 °F to +149 °F) |
Corrosion Test Method | IEC 60068-2-11, 30 days |
Environmental Test Method | ETSI EN 300 019-1-4 |
Ingress Protection Test Method | IEC 60529:2001, IP67 |
Packaging and Weights
Included | Mounting hardware |
Volume | 3.2 L |
Weight, without mounting hardware | 4.2 kg | 9.259 lb |
Product Classification
Product Type | Pentaplexer |
General Specifications
Color | Gray |
Modularity | 2-Twin |
Mounting | Pole | Wall |
Mounting Pipe Hardware | Band clamps (2) |
RF Connector Interface | 4.3-10 Female |
RF Connector Interface Body Style | Long neck |
Dimensions
Height | 147 mm | 5.787 in |
Width | 235 mm | 9.252 in |
Depth | 92 mm | 3.622 in |
Mounting Pipe Diameter Range | 43–122 mm |
Electrical Specifications
dc Pass-through | Band 1 |
Impedance | 50 ohm |
License Band, Band Pass | APT 700 | AWS 1700 | AWS 2000 | CEL 850 | CEL 900 | IMT 2100 | LMR 800 | PCS 1900 | TDD 3500 | USA 600 | USA 700 | WCS 2300 |
Electrical Specifications, Common Port
Composite Power, RMS | 500 W |
Electrical Specifications, dc Power/Alarm
dc/AISG Pass-through Method | Factory set |
dc/AISG Pass-through Path | Branch 1 |
dc/AISG Pass-through, combiner | Branch 1 |
dc/AISG Pass-through, demultiplexer | Branch 1 |
Lightning Surge Current | 5 kA |
Lightning Surge Current Waveform | 8/20 waveform |
Pass-through Current, maximum | 2 A |
Voltage | 7–30 Vdc |
Electrical Specifications, AISG
AISG Carrier | 2.176 MHz ± 100 ppm |
AISG Pass-through Current, maximum | 2 A |
Electrical Specifications
Sub-module | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 | 1 | 2 |
Branch | 1 | 2 | 3 | 4 | 5 |
Port Designation | PORT 1 617-960 | PORT 2 1850-1995 | PORT 3 AWS | PORT 4 2305-2360 | PORT 5 3300-4200 |
Electrical Specifications, Band Pass
Frequency Range, MHz | 617–960 | 1850-1995 | 1695–1780; 2110–2200 | 2305–2360 | 3300–4200 |
Insertion Loss, typical, dB | 0.15 | 0.20 | 0.20 | 0.25 | 0.15 |
Return Loss, typical, dB | 21 | 20 | 20 | 20 | 20 |
Isolation, minimum, dB | 45 @ 1695–1780 2110–2200; 50 @ 1850–1995; 50 @ 2305–2360; 50 @ 3300–4200 | 40 @ 1695–1780; 50 @ 2110–2200; 50 @ 2305–2360; 50 @ 3300–4200; 50 @ 617–960 | 40 @ 1850–1995; 40 @ 2305–2360; 50 @ 3300–4200; 50 @ 617–960 | 45 @ 2110–2200; 50 @ 1695–1780; 50 @ 1850–1995; 50 @ 3300–4200; 50 @ 617–960 | 50 @ 1695–1780 2110–2200; 50 @ 1850–1995; 50 @ 2305–2360; 50 @ 617–960 |
Input Power, RMS, maximum, W | 200 | 200 | 200 | 200 | 200 |
Input Power, PEP, maximum, W | 1,200 | 1,200 | 1,200 | 1,200 | 800 |
3rd Order PIM, typical, dBc | -161 | -161 | -161 | -161 | -161 |
3rd Order PIM Test Method | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones | Two +43 dBm CW Tones |
Mechanical Specifications
Wind Speed, maximum | 240 km/h (149 mph) |
Environmental Specifications
Operating Temperature | -40 °C to +65 °C (-40 °F to +149 °F) |
Corrosion Test Method | IEC 60068-2-11, 30 days |
Environmental Test Method | ETSI EN 300 019-1-4 |
Ingress Protection Test Method | IEC 60529:2001, IP67 |
Packaging and Weights
Included | Mounting hardware |
Volume | 3.2 L |
Weight, without mounting hardware | 4.2 kg | 9.259 lb |
Click on image to enlarge. |
Click on image to enlarge. |
Documentation & Downloads
Installation Instruction
Product Specification
Video
Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence
Warranty
Installation Instruction
Product Compliance Documentation
Product Specification
Video
Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence
Warranty
Other Ways to Browse