874032614/10 | CS24P ORG C5E 4/24 U/UTP CPK 1KFT
Base Product: CS24P
- Available in:
 - Asia
 - Australia/New Zealand
 - EMEA
 - Latin America
 - North America
 
ETL Verified Category 5e U/UTP Cable, plenum, orange jacket, 4 pair count, 1000 ft (305 m) length, CommPak
                                    Specifications
                                    
                                
                                Product classification
| Regional Availability | Asia | Australia/New Zealand | EMEA | Latin America | North America | 
| Portfolio | CommScope® | 
| Product Type | Twisted pair cable | 
General Specifications
| Product Number | CS24P | 
| ANSI/TIA Category | 5e | 
| Cable Component Type | Horizontal | 
| Cable Type | U/UTP (unshielded) | 
| Conductor Type, singles | Solid | 
| Conductors, quantity | 8 | 
| Jacket Color | Orange | 
| Note | All electrical transmission tests include swept frequency measurements | 
| Pairs, quantity | 4 | 
| Transmission Standards | ANSI/TIA-568.2-D | CENELEC EN 50288-3-1 | ISO/IEC 11801 Class D | 
Dimensions
| Cable Length | 304.8 m | 1000 ft | 
| Diameter Over Jacket, nominal | 4.877 mm | 0.192 in | 
| Jacket Thickness | 0.508 mm | 0.02 in | 
| Conductor Gauge, singles | 24 AWG | 
Cross Section Drawing
| Click on image to enlarge. | 
Electrical Specifications
| Characteristic Impedance | 100 ohm | 
| dc Resistance Unbalance, maximum | 5 % | 
| dc Resistance, maximum | 9.38 ohms/100 m | 2.859 ohms/100 ft | 
| Delay Skew, maximum | 15 ns | 
| Dielectric Strength, minimum | 1500 Vac | 2500 Vdc | 
| Mutual Capacitance at Frequency | 5.6 nF/100 m @ 1 kHz | 
| Nominal Velocity of Propagation (NVP) | 76 % | 
| Operating Frequency, maximum | 200 MHz | 
| Operating Voltage, maximum | 80 V | 
| Remote Powering | Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A | 
| Safety Voltage Rating | 300 V | 
Electrical Performance
| Click on image to enlarge. | |
| Click on image to enlarge. | 
Material Specifications
| Conductor Material | Bare copper | 
| Insulation Material | FEP | Polyolefin | 
| Jacket Material | PVC | 
Mechanical Specifications
| Pulling Tension, maximum | 11.34 kg | 25 lb | 
Environmental Specifications
| Installation temperature | 0 °C to +60 °C (+32 °F to +140 °F) | 
| Operating Temperature | -20 °C to +60 °C (-4 °F to +140 °F) | 
| Environmental Space | Plenum | 
| Flame Test Method | CMP/FT6 | NEC Article 800 | NFPA 262 | UL 444 | UL 910 | 
| Smoke Test Method | CMP/FT6 | 
Packaging and Weights
| Cable weight | 30.373 kg/km | 20.41 lb/kft | 
| Packaging Type | CommPak® box | 
Regulatory Compliance/Certifications
| Agency | Classification | 
| ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system | 
Product classification
| Regional Availability | Asia | Australia/New Zealand | EMEA | Latin America | North America | 
| Portfolio | CommScope® | 
| Product Type | Twisted pair cable | 
General Specifications
| Product Number | CS24P | 
| ANSI/TIA Category | 5e | 
| Cable Component Type | Horizontal | 
| Cable Type | U/UTP (unshielded) | 
| Conductor Type, singles | Solid | 
| Conductors, quantity | 8 | 
| Jacket Color | Orange | 
| Note | All electrical transmission tests include swept frequency measurements | 
| Pairs, quantity | 4 | 
| Transmission Standards | ANSI/TIA-568.2-D | CENELEC EN 50288-3-1 | ISO/IEC 11801 Class D | 
Dimensions
| Cable Length | 304.8 m | 1000 ft | 
| Diameter Over Jacket, nominal | 4.877 mm | 0.192 in | 
| Jacket Thickness | 0.508 mm | 0.02 in | 
| Conductor Gauge, singles | 24 AWG | 
Cross Section Drawing
| Click on image to enlarge. | 
Electrical Specifications
| Characteristic Impedance | 100 ohm | 
| dc Resistance Unbalance, maximum | 5 % | 
| dc Resistance, maximum | 9.38 ohms/100 m | 2.859 ohms/100 ft | 
| Delay Skew, maximum | 15 ns | 
| Dielectric Strength, minimum | 1500 Vac | 2500 Vdc | 
| Mutual Capacitance at Frequency | 5.6 nF/100 m @ 1 kHz | 
| Nominal Velocity of Propagation (NVP) | 76 % | 
| Operating Frequency, maximum | 200 MHz | 
| Operating Voltage, maximum | 80 V | 
| Remote Powering | Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A | 
| Safety Voltage Rating | 300 V | 
Electrical Performance
| Click on image to enlarge. | |
| Click on image to enlarge. | 
Material Specifications
| Conductor Material | Bare copper | 
| Insulation Material | FEP | Polyolefin | 
| Jacket Material | PVC | 
Mechanical Specifications
| Pulling Tension, maximum | 11.34 kg | 25 lb | 
Environmental Specifications
| Installation temperature | 0 °C to +60 °C (+32 °F to +140 °F) | 
| Operating Temperature | -20 °C to +60 °C (-4 °F to +140 °F) | 
| Environmental Space | Plenum | 
| Flame Test Method | CMP/FT6 | NEC Article 800 | NFPA 262 | UL 444 | UL 910 | 
| Smoke Test Method | CMP/FT6 | 
Packaging and Weights
| Cable weight | 30.373 kg/km | 20.41 lb/kft | 
| Packaging Type | CommPak® box | 
Regulatory Compliance/Certifications
| Agency | Classification | 
| ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system | 
                                    Documentation & Downloads
                                    
                                
                                Building Information Modeling (BIM) Objects
Calculator
Product Specification
Technical Publication
Warranty
Building Information Modeling (BIM) Objects
Calculator
Product Compliance Documentation
Product Specification
Technical Publication
Warranty
                                    Other Ways to Browse
                                    
                                
                                
                            
                                    
                                                                                    
                                                                                    
                                                                                    