Construction Materials
|
Jacket Material
|
PE
|
|
Outer Conductor Material
|
Corrugated copper
|
|
Dielectric Material
|
Foam PE
|
|
Flexibility
|
Standard
|
|
Inner Conductor Material
|
Copper-clad aluminum wire
|
|
Jacket Color
|
Black
|
|
|
|
Dimensions
|
|
Nominal Size
|
1/2 in
|
|
Cable Weight
|
0.15 lb/ft | 0.22 kg/m
|
|
Diameter Over Dielectric
|
12.954 mm | 0.510 in
|
|
Diameter Over Jacket
|
15.875 mm | 0.625 in
|
|
Inner Conductor OD
|
4.8260 mm | 0.1900 in
|
|
Outer Conductor OD
|
13.970 mm | 0.550 in
|
|
|
|
Electrical Specifications
|
|
Cable Impedance
|
50 ohm ±1 ohm
|
|
Capacitance
|
23.1 pF/ft | 75.8 pF/m
|
|
dc Resistance, Inner Conductor
|
0.450 ohms/kft | 1.480 ohms/km
|
|
dc Resistance, Outer Conductor
|
0.820 ohms/kft | 2.690 ohms/km
|
|
dc Test Voltage
|
4000 V
|
|
Inductance
|
0.190 µH/m | 0.058 µH/ft
|
|
Insulation Resistance
|
100000 Mohms•km
|
|
Jacket Spark Test Voltage (rms)
|
8000 V
|
|
Operating Frequency Band
|
1 – 8800 MHz
|
|
Peak Power
|
40.0 kW
|
|
Pulse Reflection
|
0.5%
|
|
Velocity
|
88%
|
|
|
|
Environmental Specifications
|
|
Installation Temperature
|
-40 °C to +60 °C (-40 °F to +140 °F)
|
|
Operating Temperature
|
-55 °C to +85 °C (-67 °F to +185 °F)
|
|
Storage Temperature
|
-70 °C to +85 °C (-94 °F to +185 °F)
|
|
|
|
General Specifications
|
|
Brand
|
HELIAX®
|
|
|
|
Mechanical Specifications
|
|
Bending Moment
|
3.8 N-m | 2.8 ft lb
|
|
Flat Plate Crush Strength
|
110.0 lb/in | 2.0 kg/mm
|
|
Minimum Bend Radius, Multiple Bends
|
127.00 mm | 5.00 in
|
|
Minimum Bend Radius, Single Bend
|
50.80 mm | 2.00 in
|
|
Number of Bends, minimum
|
15
|
|
Number of Bends, typical
|
50
|
|
Tensile Strength
|
113 kg | 250 lb
|
|
|
|
Note
|
|
Performance Note
|
Values typical, unless otherwise stated
|
|
|
|
Standard Conditions
|
|
Attenuation, Ambient Temperature
|
20 °C | 68 °F
|
|
Average Power, Ambient Temperature
|
40 °C | 104 °F
|
|
Average Power, Inner Conductor Temperature
|
100 °C | 212 °F
|