USL10G-SHLD
Base Product
        
            - Available in:
- North America
SL-Series Modular Jack, RJ45, Cat6A Shielded
                    Configure Product Variants
                
                
                        
    
    
    
    
                                Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
                                Update your browser for more security, speed, functionality and experience on this site.
                            
                                    Specifications
                                    
                                
                                Product classification
| Regional Availability | North America | 
| Portfolio | Uniprise® | 
| Product Type | Modular jack | 
| Product Series | USL Series | 
General Specifications
| ANSI/TIA Category | 6A | 
| Cable Type | Shielded | 
| Conductor Type | Solid | Stranded | 
| Mounting | SL Series faceplates and panels | 
| Outlet Type | Standard | 
| Termination Tool | JTT Termination tool | 
| Termination Type | IDC | 
| Transmission Standards | ANSI/TIA-568.2-D | ISO/IEC 11801 Class EA | 
| Wiring | T568A | T568B | 
Dimensions
| Panel Cutout, recommended | 14.78 x 20.07 mm (0.58 x 0.79 in) | 
| Panel Thickness, recommended | 1.6 mm | 0.063 in | 
| Height | 16.13 mm | 0.635 in | 
| Width | 14.44 mm | 0.569 in | 
| Depth | 36.8 mm | 1.449 in | 
| Compatible Cable Diameter, maximum | 8.5 mm | 0.335 in | 
| Compatible Insulated Conductor Diameter, maximum | 1.6 mm | 0.063 in | 
| Contact Plating Thickness | 1.27 µm | 
| Compatible Conductor Gauge, solid | 22–24 AWG | 
| Compatible Conductor Gauge, stranded | 24–26 AWG | 
Electrical Specifications
| Contact Resistance Variation, maximum | 20 mOhm | 
| Contact Resistance, maximum | 100 mOhm | 
| Current Rating at Temperature | 1.5 A @ 20 °C | 1.5 A @ 68 °F | 
| Dielectric Withstand Voltage, RMS, conductive surface | 1,500 Vac @ 60 Hz | 
| Dielectric Withstand Voltage, RMS, contact-to-contact | 1,000 Vac @ 60 Hz | 
| Insulation Resistance, minimum | 500 MOhm | 
| Remote Powering | Fully supports the safe delivery of power over LAN cabling described by IEEE 802.3bt (Type 4) and complies with the unmating under electrical load requirements prescribed by IEC 60512-99-002 | 
| PoE Durability | Supports IEEE 802.3bt Type 4 (90 W) applications greater than 3000 plug to jack mating cycles | 
| Safety Voltage Rating | 150 Vac | 
Material Specifications
| Contact Base Material | Beryllium copper | 
| Contact Plating Material | Gold | 
| IDC Termination Material | Phosphor Bronze | 
| Material Type | Zamak | PC+ABS | 
| Termination Contact Plating | Tin | 
Mechanical Specifications
| Plug Retention Force, minimum | 50 N | 11.24 lbf | 
| Plug to Jack Mating Cycles | Complies to IEC 60603-7 series | 
Environmental Specifications
| Operating Temperature | -10 °C to +60 °C (+14 °F to +140 °F) | 
| Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) | 
| Flammability Rating | UL 94 V-0 | 
| Safety Standard | cULus | 
Product classification
| Regional Availability | North America | 
| Portfolio | Uniprise® | 
| Product Type | Modular jack | 
| Product Series | USL Series | 
General Specifications
| ANSI/TIA Category | 6A | 
| Cable Type | Shielded | 
| Conductor Type | Solid | Stranded | 
| Mounting | SL Series faceplates and panels | 
| Outlet Type | Standard | 
| Termination Tool | JTT Termination tool | 
| Termination Type | IDC | 
| Transmission Standards | ANSI/TIA-568.2-D | ISO/IEC 11801 Class EA | 
| Wiring | T568A | T568B | 
Dimensions
| Panel Cutout, recommended | 14.78 x 20.07 mm (0.58 x 0.79 in) | 
| Panel Thickness, recommended | 1.6 mm | 0.063 in | 
| Height | 16.13 mm | 0.635 in | 
| Width | 14.44 mm | 0.569 in | 
| Depth | 36.8 mm | 1.449 in | 
| Compatible Cable Diameter, maximum | 8.5 mm | 0.335 in | 
| Compatible Insulated Conductor Diameter, maximum | 1.6 mm | 0.063 in | 
| Contact Plating Thickness | 1.27 µm | 
| Compatible Conductor Gauge, solid | 22–24 AWG | 
| Compatible Conductor Gauge, stranded | 24–26 AWG | 
Electrical Specifications
| Contact Resistance Variation, maximum | 20 mOhm | 
| Contact Resistance, maximum | 100 mOhm | 
| Current Rating at Temperature | 1.5 A @ 20 °C | 1.5 A @ 68 °F | 
| Dielectric Withstand Voltage, RMS, conductive surface | 1,500 Vac @ 60 Hz | 
| Dielectric Withstand Voltage, RMS, contact-to-contact | 1,000 Vac @ 60 Hz | 
| Insulation Resistance, minimum | 500 MOhm | 
| Remote Powering | Fully supports the safe delivery of power over LAN cabling described by IEEE 802.3bt (Type 4) and complies with the unmating under electrical load requirements prescribed by IEC 60512-99-002 | 
| PoE Durability | Supports IEEE 802.3bt Type 4 (90 W) applications greater than 3000 plug to jack mating cycles | 
| Safety Voltage Rating | 150 Vac | 
Material Specifications
| Contact Base Material | Beryllium copper | 
| Contact Plating Material | Gold | 
| IDC Termination Material | Phosphor Bronze | 
| Material Type | Zamak | PC+ABS | 
| Termination Contact Plating | Tin | 
Mechanical Specifications
| Plug Retention Force, minimum | 50 N | 11.24 lbf | 
| Plug to Jack Mating Cycles | Complies to IEC 60603-7 series | 
Environmental Specifications
| Operating Temperature | -10 °C to +60 °C (+14 °F to +140 °F) | 
| Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) | 
| Flammability Rating | UL 94 V-0 | 
| Safety Standard | cULus | 
                                    Documentation & Downloads
                                    
                                