Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

FFT-Q | FFT*-*Q Series Full-Feature Equalizable Taps

Base Product
  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

1.2 GHz Full-Feature Equalizable Taps

Configure Product Variants
Contact Us for a Quote
Specifications
Finish making your selections or clear them to view relevant specifications.
Get Connected to the Access Technologies Resource Center

Find manuals, quick guides, data sheets, videos and much more!

Explore Access Technologies Resource Center

Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
Update your browser for more security, speed, functionality and experience on this site.

Update browser

Product Variants

Configure and display product variants of FFT-Q | FFT*-*Q Series Full-Feature Equalizable Taps by selecting options

Loading...
Product
Regional Availability Insertion Loss, tap, nominal Product Type Product Series Bandwidth Number of Ports Government Requirements
594944-001-00 | FFT2-4TQ 594944-001-00 | FFT2-4TQ
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 4 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 4 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-002-00 | FFT2-7Q 594944-002-00 | FFT2-7Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 7 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 7 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-003-00 | FFT2-10Q 594944-003-00 | FFT2-10Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 10 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 10 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-004-00 | FFT2-12Q 594944-004-00 | FFT2-12Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 12 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 12 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-005-00 | FFT2-14Q 594944-005-00 | FFT2-14Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 14 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 14 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-006-00 | FFT2-17Q 594944-006-00 | FFT2-17Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 17 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 17 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-007-00 | FFT2-20Q 594944-007-00 | FFT2-20Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 20 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 20 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
594944-008-00 | FFT2-23Q 594944-008-00 | FFT2-23Q
FFT Complete RF Tap, 2-way, 1.2 GHz Full-Feature Equalizable, 23 dB nominal tap value, 12 A Power passing
Asia | Australia/New Zealand | EMEA | Latin America | North America 23 dB RF tap FFT 5 – 1218 MHz MHz 2 Build America Buy America (BABA) compliant*
Features and Benefits
The ARRIS FFT‐Q 1.2 GHz series equalizable taps offer improved return path performance for advanced two‐way HFC systems while maintaining backward compatibility with previous FFT install base. FFT taps allow for signal conditioning with optional plug‐in, field configurable modules that include cable equalizers, return path attenuators, and cable simulators. These plug‐ins allow for drop signal conditioning without affecting the main feederline path.
  • Support DOCSIS® 3.1 expanded bandwidth up to 1218 MHz
  • Improve network performance with signal conditioning plug‐ins
  • High quality RF connection with auto‐seize F‐connectors
  • Maintain existing install base with compatibility back to “F” series FFT housings
  • High level of network resilience with 6kV surge resistance on feederline and F‐ports
  • Maintain RF and AC connections with faceplate removed with integrated bypass capability

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type RF tap

Electrical Specifications

Return Loss at Frequency Band, tap 16 dB @ 5–9 MHz, 17 dB @ 10–749 MHz, 17 dB @ 750–1000 MHz, 16 dB @ 1001–1218 MHz
Hum Modulation at Operating Frequency 60 dB minimum @ 5–10 MHz, 65 dB minimum @ 11–750 MHz, 60 dB minimum @ 751–1000 MHz, 55 dB minimum @ 1001–1218 MHz
Isolation at Frequency Band, tap to tap 21 dB @ 5–9 MHz, 25 dB @ 10–85 MHz, 27 dB @ 86–300 MHz, 23 dB @ 301–749 MHz, 20 dB @ 750–1218 MHz
Power Passing at 60/90V, maximum 12 A
Surge Protection, F port 6 kV Combination Wave
Surge Protection, input/output ports 6 kV Combination Wave

Environmental Specifications

Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F)

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type RF tap

Electrical Specifications

Return Loss at Frequency Band, tap 16 dB @ 5–9 MHz, 17 dB @ 10–749 MHz, 17 dB @ 750–1000 MHz, 16 dB @ 1001–1218 MHz
Hum Modulation at Operating Frequency 60 dB minimum @ 5–10 MHz, 65 dB minimum @ 11–750 MHz, 60 dB minimum @ 751–1000 MHz, 55 dB minimum @ 1001–1218 MHz
Isolation at Frequency Band, tap to tap 21 dB @ 5–9 MHz, 25 dB @ 10–85 MHz, 27 dB @ 86–300 MHz, 23 dB @ 301–749 MHz, 20 dB @ 750–1218 MHz
Power Passing at 60/90V, maximum 12 A
Surge Protection, F port 6 kV Combination Wave
Surge Protection, input/output ports 6 kV Combination Wave

Environmental Specifications

Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F)