Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

O-DF

Base Product
  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

Fiber Optic Cable, Drop, Outdoor Arid Core Gel-Filled Tubes, Flat

Configure Product Variants
Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
Update your browser for more security, speed, functionality and experience on this site.

Update browser

Product Variants

Configure and display product variants of O-DF by selecting options

Loading...
Product
Regional Availability Government Requirements Portfolio Product Series Product Type Environmental Space Construction Type Jacket Color Total Fiber Count Jacket Material Fiber Type Cable Type Jacket Marking Subunit Type
810010250/50 | O-012-DF-8W-F12NS (5000') 810010250/50 | O-012-DF-8W-F12NS (5000')
Fiber outdoor drop cable, LightScope® ZWP Self-Supporting All-Dielectric, Singlemode G.652.D and G.657.A1, 12 fiber Arid Core construction, Gel-filled, central loose tube, Feet jacket marking, Black jacket color, 5000 ft
Asia | Australia/New Zealand | EMEA | Latin America | North America Build America Buy America (BABA) compliant* CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 12 PE G.652.D and G.657.A1 | G.652.D and G.657.A1 Central loose tube Feet Gel-filled
810010251/20 | O-024-DF-8W-F24NS/30G (2000') 810010251/20 | O-024-DF-8W-F24NS/30G (2000')
Fiber outdoor drop cable, LightScope® ZWP Self-Supporting All-Dielectric, Singlemode G.652.D and G.657.A1, 24 fiber, Arid Core construction, Gel-filled, central loose tube, no ripcords, Feet jacket marking, Black jacket color, 2000 ft
Asia | Australia/New Zealand | EMEA | Latin America | North America Build America Buy America (BABA) compliant* CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 24 PE G.652.D and G.657.A1 | G.652.D and G.657.A1 Central loose tube Feet Gel-filled
810010252/50 | O-024-DF-8W-F24NS/30G (5000') 810010252/50 | O-024-DF-8W-F24NS/30G (5000')
Fiber outdoor drop cable, LightScope® ZWP Self-Supporting All-Dielectric, Singlemode G.652.D and G.657.A1, 24 fiber, Arid Core construction, Gel-filled, central loose tube, no ripcords, Feet jacket marking, Black jacket color, 5000 ft
Asia | Australia/New Zealand | EMEA | Latin America | North America Build America Buy America (BABA) compliant* CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 24 PE G.652.D and G.657.A1 | G.652.D and G.657.A1 Central loose tube Feet Gel-filled
810010309/DB | O-001-DF-8G1-F01OR/SP29 810010309/DB | O-001-DF-8G1-F01OR/SP29
Fiber Universal Service Drop Cable, dielectric, with 900um Buffer, 1-fiber, Singlemode G.657.A2/B2,Gel-free
Asia | Australia/New Zealand | EMEA | Latin America | North America Build America Buy America (BABA) compliant* CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Orange 1 PE G.657.A2/B2 | G.657.A2/B2 Drop Feet Gel-free
810010323/DB | O-001-DF-8G1-F01NS/TB 810010323/DB | O-001-DF-8G1-F01NS/TB
Self-Supporting All-Dielectric Outdoor Drop Cable
Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 1 PE G.657.A2/B2 | G.657.A2/B2 Central loose tube Feet Gel-free
810010324/DB | O-001-DF-HY-F01NS/TB/8G1001/1X24AWG 810010324/DB | O-001-DF-HY-F01NS/TB/8G1001/1X24AWG
Self-Supporting Tonable Outdoor Drop Cable
Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® O-DF Hybrid cable | fiber and tone-wire Aerial | self-support | Buried Non-armored Black 1 PE G.657.A2/B2 | G.657.A2/B2 Drop Feet Gel-free
810010363/DB | O-036-DF-8W-F12NS/15G 810010363/DB | O-036-DF-8W-F12NS/15G
Fiber outdoor drop cable, LightScope® ZWP Self-Supporting All-Dielectric, Singlemode G.652.D and G.657.A1, Arid Core construction, Gel-filled, central loose tube, no ripcords, Feet jacket marking, Black jacket color
Asia | Australia/New Zealand | EMEA | Latin America | North America Build America Buy America (BABA) compliant* CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 36 PE G.652.D and G.657.A1 | G.652.D and G.657.A1 Central loose tube Feet Gel-filled
810010437/DB | O-001-DF-8G-F01NS/TB 810010437/DB | O-001-DF-8G-F01NS/TB
Self-Supporting All-Dielectric Outdoor Drop Cable
Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® O-DF Fiber drop cable Aerial | self-support | Buried Non-armored Black 1 PE G.657.A2/B2 | G.657.A2/B2 Central loose tube Feet Gel-free
Features and Benefits
  • Fiber drop cables are typically used between the fiber terminal and the building or home and available for various indoor or outdoor applications
  • Fiber drop cables are engineered to withstand the most demanding environmental conditions, including sun, heat, cold, moisture and heavy RF interference
  • Superior mechanical and optical performance with unmatched stability and quality

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber drop cable
Product Series O-DF

General Specifications

Cable Type Central loose tube
Construction Type Non-armored
Jacket Color Black

Ordering Tree

Click on image to enlarge.

Mechanical Specifications

Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature -30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards ANSI/ICEA S-110-717
Environmental Space Aerial, self-support | Buried
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze -2 °C | 28.400 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Drip 70 °C | 158.000 °F
Drip Test Method FOTP-81 | IEC 60794-1 E14
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber drop cable
Product Series O-DF

General Specifications

Cable Type Central loose tube
Construction Type Non-armored
Jacket Color Black

Mechanical Specifications

Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature -30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards ANSI/ICEA S-110-717
Environmental Space Aerial, self-support | Buried
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Cable Freeze -2 °C | 28.400 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Drip 70 °C | 158.000 °F
Drip Test Method FOTP-81 | IEC 60794-1 E14
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1
Click on image to enlarge.