Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

D-CN

Base Product
  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

Fiber Optic Cable, Outdoor Arid Core Gel-Free Tubes, Central Tube All-Dielectric

Configure Product Variants
Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
Update your browser for more security, speed, functionality and experience on this site.

Update browser

Product Variants

Configure and display product variants of D-CN by selecting options

Loading...
Product
Jacket Marking Regional Availability Government Requirements Portfolio Product Series Product Type Cable Type Construction Type Jacket Color Total Fiber Count Fiber Type Environmental Space Subunit Type
760213678 | D-024-CN-RB-F12NS/5K/99A 760213678 | D-024-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, Dry Central Tube Ribbon, 24 fibers, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 24 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213686 | D-036-CN-RB-F12NS/5K/99A 760213686 | D-036-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, 36 fibers, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 36 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213694 | D-048-CN-RB-F12NS/5K/99A 760213694 | D-048-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, 48 fibers, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 48 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213702 | D-060-CN-RB-F12NS/5K/99A 760213702 | D-060-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, 60 fibers, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 60 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213710 | D-072-CN-RB-F12NS/5K/99A 760213710 | D-072-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, 72 fiber, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 72 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213728 | D-096-CN-RB-F12NS/5K/99A 760213728 | D-096-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, Arid-Core, 96 fiber, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 96 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213736 | D-144-CN-RB-F12NS/5K/99A 760213736 | D-144-CN-RB-F12NS/5K/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, 144 fiber, Arid-Core, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 144 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
760213744 | D-192-CN-RB-F12NS/5X/99A 760213744 | D-192-CN-RB-F12NS/5X/99A
Fiber OSP Cable, Non-Armored, All-Dielectric, 192 fiber, Arid-Core, Dry Central Tube Ribbon, Multimode OM4 bend insensitive, Gel-free, Feet jacket marking, Black jacket color
Feet Asia | Australia/New Zealand | EMEA | Latin America | North America CommScope® D-CN Fiber OSP cable Ribbon central tube Non-armored Black 192 OM4 | bend insensitive | OM4 | bend insensitive Aerial | lashed | Buried Gel-free
Features and Benefits
  • CommScope’s outside plant fiber cables are made with high-performance, standards-compliant materials
  • The portfolio includes both armored and dielectric designs available with dry or gel-filled tubes
  • Superior mechanical and optical performance with unmatched stability and quality

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber OSP cable
Product Series D-CN

General Specifications

Cable Type Ribbon central tube
Construction Type Non-armored
Subunit Type Gel-free
Jacket Color Black

Ordering Tree

Click on image to enlarge.

Mechanical Specifications

Tensile Load, long term, maximum 800 N | 179.847 lbf
Tensile Load, short term, maximum 2700 N | 606.984 lbf
Compression 22 N/mm | 125.623 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 25 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards ANSI/ICEA S-87-640 | Telcordia GR-20
Environmental Space Aerial, lashed | Buried
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Portfolio CommScope®
Product Type Fiber OSP cable
Product Series D-CN

General Specifications

Cable Type Ribbon central tube
Construction Type Non-armored
Subunit Type Gel-free
Jacket Color Black

Mechanical Specifications

Tensile Load, long term, maximum 800 N | 179.847 lbf
Tensile Load, short term, maximum 2700 N | 606.984 lbf
Compression 22 N/mm | 125.623 lb/in
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 25 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7

Environmental Specifications

Installation temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards ANSI/ICEA S-87-640 | Telcordia GR-20
Environmental Space Aerial, lashed | Buried
Jacket UV Resistance UV stabilized
Water Penetration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5

Environmental Test Specifications

Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1
Click on image to enlarge.

Product Specification

Product Specification