Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

FST

Base Product
  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

FST Flexible Service Terminal, factory-sealed

Configure Product Variants
Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Your web browser (Internet Explorer 11 or lower) is out of date and the functions below will not work with Internet Explorer.
Update your browser for more security, speed, functionality and experience on this site.

Update browser

Product Variants Show All Clear

Configure and display product variants of FST by selecting options

Loading...
Product
Regional Availability Product Brand Product Series Product Type Cable Length, stub Cable Type Distribution Type Port Type Port, quantity Stub Type
760242039 | FST-S-HH04-N00-04 760242039 | FST-S-HH04-N00-04
FST Flexible Service Terminal, 4 Port, 4 Full-size hardened Adapters at drop side, 1x4 Splitter, 1 Full-size Adapter at input side, 1.5 ft/0.457 m
Asia | Latin America | North America FST-S Access terminal | with splitter 1.5 ft (0.5 m) Dielectric - Flat - Loose Tube 1 x 4 splitter Hardened full-size SC/APC 4 Hardened full-size SC/APC
760242040 | FST-S-HH08-N00-08 760242040 | FST-S-HH08-N00-08
FST Flexible Service Terminal, 8 Port, 8 Full-size hardened Adapters at drop side, 1x8 Splitter, 1 Full-size Adapter at input side, 1.5 ft/0.457 m
Asia | Latin America | North America FST-S Access terminal | with splitter 1.5 ft (0.5 m) Dielectric - Flat - Loose Tube 1 x 8 splitter Hardened full-size SC/APC 8 Hardened full-size SC/APC
760243083 | FST-T2-0610-A0500F 760243083 | FST-T2-0610-A0500F
FST-T2 Flexible Service Terminal, 12f, 6 Port x 2 Fiber, 6 HMFOC Adapters (Jack/male/pinned, 2 fibers per adapter at drop side, Stub at feeder side, black, 500 ft/152 m
North America FST-T2 Access terminal | with multi-fiber port 500 ft (152 m) Dielectric - Loose Tube 6 ports Hardened multi-fiber (HMFOC) jack | male/pinned 6 Stub tail
760244829 | FST-B-PH04-J24-N 760244829 | FST-B-PH04-J24-N
FST Flexible Service Terminal, Branch, 1 HMFOC Input Plug (Black), 4 Single-fiber Branches (Full-size Adapters) and 2 Multi-fiber Branches (4-Fiber HMFOC/Jack), Input HMFOC/Plug (Female/No pin), 1.3 ft/0.4 m
Asia | Latin America | North America FST-B Access terminal | with branch 1.5 ft (0.5 m) Dielectric - Flat - Loose Tube 4 ports Hardened full-size SC/APC 4 Hardened multi-fiber (HMFOC) plug
760245189 | FST-T2-0610-A0200F 760245189 | FST-T2-0610-A0200F
FST-T2 Flexible Service Terminal, 12f, 6 Port x 2 Fiber, 6 HMFOC Adapters (Jack/male/pinned), 2 fibers per adapter at drop side, Stub at feeder side, black, 200 ft/60 m
North America FST-T2 Access terminal | with multi-fiber port 200 ft (60 m) Dielectric - Loose Tube 6 ports Hardened multi-fiber (HMFOC) jack | male/pinned 6 Stub tail
760245190 | FST-T2-0610-A0250F 760245190 | FST-T2-0610-A0250F
FST-T2 Flexible Service Terminal, 12f, 6 Port x 2 Fiber, 6 HMFOC Adapters (Jack/male/pinned), 2 fibers per adapter at drop side, Stub at feeder side, black, 250 ft/76 m
North America FST-T2 Access terminal | with multi-fiber port 250 ft (76 m) Dielectric - Loose Tube 6 ports Hardened multi-fiber (HMFOC) jack | male/pinned 6 Stub tail
760245191 | FST-T2-0610-A0750F 760245191 | FST-T2-0610-A0750F
FST-T2 Flexible Service Terminal, 12f, 6 Port x 2 Fiber, 6 HMFOC Adapters (Jack/male/pinned), 2 fibers per adapter at drop side, Stub at feeder side, black, 750 ft/228 m
North America FST-T2 Access terminal | with multi-fiber port 500 ft (152 m) Dielectric - Loose Tube 6 ports Hardened multi-fiber (HMFOC) jack | male/pinned 6 Stub tail
760245192 | FST-T2-0610-A1000F 760245192 | FST-T2-0610-A1000F
FST-T2 Flexible Service Terminal, 12f, 6 Port x 2 Fiber, 6 HMFOC Adapters (Jack/male/pinned), 2 fibers per adapter at drop side, Stub at feeder side, black, 1000 ft/304 m
North America FST-T2 Access terminal | with multi-fiber port 1000 ft (304 m) Dielectric - Loose Tube 6 ports Hardened multi-fiber (HMFOC) jack | male/pinned 6 Stub tail
Features and Benefits
The flexible service terminal (FST) series is designed specially for fast, easy network connections in space-constrained environments. A small terminal unit attached to staggered-length connector cables gives installers maximum flexibility in the tightest, most challenging install situations. Hardened fiber stubs make for fast, reliable, plugand-play distribution to customer premises. The FST’s unique design also simplifies maintenance, as the flexible hardened adapter stubs are easy to clean and reconnect without removing the terminal from its installed position.

This factory-sealed terminal withstands harsh outside plant conditions, and is an ideal option for spaces such as handholes or congested pits where moisture is possible. The small unit’s flexible structure gives technicians a wealth of install options— it’s a simple solution that can reduce or even eliminate the costs of civil works and construction.

The FST series consists of three main families:

The FST-B features four single-fiber pre-connectorized, hardened, full-size connector adapter drops, and two four-fiber branch drops with HMFOC connectors.

The FST-S is available with a factory integrated1x4 or 1x8 planar splitter and full-size connectors.

The FST-T terminal features pre-connectorized, hardened, full-size or miniaturized DLX single-fiber adapter drops and an HMFOC stub.

  • Flexible Service Terminals incorporate hardened connector technology that is designed to withstand the rugged outside plant environment
  • Hardened connectors are factory-terminated and environmentally sealed for use in optical drop cable deployments
  • Flexible structure plus very small branching unit, allowing installation in constrained spaces
  • Hardened connectors are factory-integrated and environmentally sealed for use in optical drop cable deployments

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type Access terminal, with splitter/tap | Access terminal, without splitter/tap
Product Series FST | FST-B | FST-S | FST-T | FST-T2

General Specifications

Cable Type Dielectric - Flat - Loose Tube | Dielectric - Loose Tube | Toneable - Flat - Loose Tube
Distribution Type 1 x 2 splitter | 1 x 4 splitter | 1 x 8 splitter | 12 ports | 2 ports | 4 ports | 6 ports | 8 ports
Enclosure Color Black
Mounting Handhole | Pedestal
Port Type Hardened full-size SC/APC | Hardened mini-size DLX | Hardened multi-fiber (HMFOC) jack, male/pinned
Stub Type Hardened full-size SC/APC | Hardened multi-fiber (HMFOC) jack, no pins | Stub tail

Ordering Tree

Click on image to enlarge.

Material Specifications

Enclosure Material Type Hardened plastic

Environmental Specifications

Relative Humidity 5%–100%, condensing
Environmental Space Above ground | Below ground | Buried
UV Resistance UV stabilized

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type Access terminal, with splitter/tap | Access terminal, without splitter/tap
Product Series FST | FST-B | FST-S | FST-T | FST-T2

General Specifications

Cable Type Dielectric - Flat - Loose Tube | Dielectric - Loose Tube | Toneable - Flat - Loose Tube
Distribution Type 1 x 2 splitter | 1 x 4 splitter | 1 x 8 splitter | 12 ports | 2 ports | 4 ports | 6 ports | 8 ports
Enclosure Color Black
Mounting Handhole | Pedestal
Port Type Hardened full-size SC/APC | Hardened mini-size DLX | Hardened multi-fiber (HMFOC) jack, male/pinned
Stub Type Hardened full-size SC/APC | Hardened multi-fiber (HMFOC) jack, no pins | Stub tail

Material Specifications

Enclosure Material Type Hardened plastic

Environmental Specifications

Relative Humidity 5%–100%, condensing
Environmental Space Above ground | Below ground | Buried
UV Resistance UV stabilized
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
CHINA-ROHS Below maximum concentration value
REACH-SVHC Compliant as per SVHC revision on www.commscope.com/ProductCompliance
UK-ROHS Compliant

Installation Instruction

Product Selection Guide

Product Specification

Installation Instruction

Product Selection Guide

Product Specification