810009821/DB | C-008-CN-8W-M08BK/32G/AY/D

Base Product: C-CN

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA

Fiber indoor/outdoor cable, LightScope ZWP® , Gel-Filled loose tube, 8 fiber, Singlemode G.652.D and G.657.A1, Meters jacket marking, Black jacket color, Dca flame rating

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series C-CN

General Specifications

Cable Type Central loose tube
Subunit Type Gel-filled
Jacket Color Black
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB  F.O. CABLE 810009821/DB INT/EXT GLT 8X9/125 OS2 EN50575 CLASS D [Serial NUMBER] [METRE MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 8
Total Fiber Count 8

Dimensions

Cable Length 2000 m | 6561.68 ft
Buffer Tube/Subunit Diameter 3.2 mm | 0.126 in
Diameter Over Jacket 7 mm | 0.276 in

Representative Image

Click on image to enlarge.

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, loaded 129.5 mm | 5.098 in
Minimum Bend Radius, unloaded 80 mm | 3.15 in
Tensile Load, long term, maximum 650 N | 146.126 lbf
Tensile Load, short term, maximum 1250 N | 281.011 lbf
Cable Crush Resistance, maximum 12 N/mm | 68.522 lb/in
Compression Test Method IEC 60794-1-2 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4
Twist 10 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.652.D and G.657.A1

Environmental Specifications

Installation temperature -25 °C to +70 °C (-13 °F to +158 °F)
Operating Temperature -25 °C to +70 °C (-13 °F to +158 °F)
Storage Temperature -25 °C to +70 °C (-13 °F to +158 °F)
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s2
EN50575 CPR Cable EuroClass Droplets Rating d2
EN50575 CPR Cable EuroClass Acidity Rating a2
Environmental Space Universal Low Smoke Zero Halogen (ULSZH)
Water Penentration 336 h
Water Penentration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -25 °C to +70 °C (-13 °F to +158 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 50 kg/km | 33.598 lb/kft

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA
Portfolio CommScope®
Product Type Fiber indoor/outdoor cable
Product Series C-CN

General Specifications

Cable Type Central loose tube
Subunit Type Gel-filled
Jacket Color Black
Jacket Marking Meters
Jacket Marking Method Inkjet
Jacket Marking Text COMMSCOPE GB  F.O. CABLE 810009821/DB INT/EXT GLT 8X9/125 OS2 EN50575 CLASS D [Serial NUMBER] [METRE MARK]
Subunit, quantity 1
Fibers per Subunit, quantity 8
Total Fiber Count 8

Dimensions

Cable Length 2000 m | 6561.68 ft
Buffer Tube/Subunit Diameter 3.2 mm | 0.126 in
Diameter Over Jacket 7 mm | 0.276 in

Material Specifications

Jacket Material Low Smoke Zero Halogen (LSZH)

Mechanical Specifications

Minimum Bend Radius, loaded 129.5 mm | 5.098 in
Minimum Bend Radius, unloaded 80 mm | 3.15 in
Tensile Load, long term, maximum 650 N | 146.126 lbf
Tensile Load, short term, maximum 1250 N | 281.011 lbf
Cable Crush Resistance, maximum 12 N/mm | 68.522 lb/in
Compression Test Method IEC 60794-1-2 E3
Impact 5 N-m | 44.254 in lb
Impact Test Method IEC 60794-1 E4
Twist 10 cycles
Twist Test Method IEC 60794-1 E7

Optical Specifications

Fiber Type G.652.D and G.657.A1

Environmental Specifications

Installation temperature -25 °C to +70 °C (-13 °F to +158 °F)
Operating Temperature -25 °C to +70 °C (-13 °F to +158 °F)
Storage Temperature -25 °C to +70 °C (-13 °F to +158 °F)
EN50575 CPR Cable EuroClass Fire Performance Dca
EN50575 CPR Cable EuroClass Smoke Rating s2
EN50575 CPR Cable EuroClass Droplets Rating d2
EN50575 CPR Cable EuroClass Acidity Rating a2
Environmental Space Universal Low Smoke Zero Halogen (ULSZH)
Water Penentration 336 h
Water Penentration Test Method IEC 60794-1 F5

Environmental Test Specifications

Temperature Cycle -25 °C to +70 °C (-13 °F to +158 °F)
Temperature Cycle Test Method IEC 60794-1-2 F1

Packaging and Weights

Cable weight 50 kg/km | 33.598 lb/kft
Click on image to enlarge.