Warning Icon
This product will be discontinued on: December 30, 2024

For other alternatives, please contact us for more information.

1 Replacement products available
  • E16R01P97
    Tower Mounted Amplifier, Dual GSM/UMTS 900 with AISG

E15R02P15

Tower Mounted Amplifier, Dual GSM SB 900 MHz with AISG

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Product Type 1-BTS:1-ANT (Uniplex) | Tower mounted amplifier

General Specifications

Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 7-16 DIN Female
RF Connector Interface Body Style Long neck

Dimensions

Height 260 mm | 10.236 in
Width 170 mm | 6.693 in
Depth 140 mm | 5.512 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 40–160 mm

Outline Drawing

Click on image to enlarge.

Electrical Specifications

License Band, LNA CEL 900

Electrical Specifications, dc Power/Alarm

dc Switching/Redundancy Yes
Lightning Surge Current 5 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 100 mA @ 12 Vdc
Operating Current Tolerance ±20 mA
Voltage 7–30 Vdc
Alarm Current, CWA Mode 185 mA ±15 mA

Electrical Specifications, AISG

AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9
Protocol AISG 2.0
Voltage, AISG Mode 10–30 Vdc

Electrical Specifications

Sub-module 1 | 2
Branch 1
Port Designation ANT
License Band CEL 900, LNA

Electrical Specifications, Rx Uplink

Frequency Range, MHz 898–915
Bandwidth, MHz 17.00
Gain, nominal, dB 13.0
Gain Tolerance, dB ±1
Noise Figure, maximum, dB 1.8
Noise Figure, typical, dB 1.5
Output IP3, minimum, dBm 23
Return Loss, minimum, dB 18
Insertion Loss - Bypass Mode, typical, dB 2.8
Return Loss - Bypass Mode, typical, dB 18
TX Band Rejection, minimum, dB 80

Electrical Specifications, Tx Downlink

Frequency Range, MHz 943–960
Bandwidth, MHz 17.00
Insertion Loss, maximum, dB 0.60
Return Loss, minimum, dB 18
RX Band Rejection, minimum, dB 70
Input Power, RMS, maximum, W 200
Input Power, PEP, maximum, W 5,000
3rd Order PIM, maximum, dBc -155
3rd Order PIM Test Method Two +43 dBm carriers
5th Order PIM, maximum, dBc -163
5th Order PIM Test Method Two +43 dBm carriers

Block Diagram

Click on image to enlarge.

Material Specifications

Finish Painted

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Weight, net 8 kg | 17.637 lb

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Product Type 1-BTS:1-ANT (Uniplex) | Tower mounted amplifier

General Specifications

Color Gray
Modularity 2-Twin
Mounting Pole | Wall
Mounting Pipe Hardware Band clamps (2)
RF Connector Interface 7-16 DIN Female
RF Connector Interface Body Style Long neck

Dimensions

Height 260 mm | 10.236 in
Width 170 mm | 6.693 in
Depth 140 mm | 5.512 in
Ground Screw Diameter 6 mm | 0.236 in
Mounting Pipe Diameter Range 40–160 mm

Electrical Specifications

License Band, LNA CEL 900

Electrical Specifications, dc Power/Alarm

dc Switching/Redundancy Yes
Lightning Surge Current 5 kA
Lightning Surge Current Waveform 8/20 waveform
Operating Current at Voltage 100 mA @ 12 Vdc
Operating Current Tolerance ±20 mA
Voltage 7–30 Vdc
Alarm Current, CWA Mode 185 mA ±15 mA

Electrical Specifications, AISG

AISG Connector 8-pin DIN Female
AISG Connector Standard IEC 60130-9
Protocol AISG 2.0
Voltage, AISG Mode 10–30 Vdc

Electrical Specifications

Sub-module 1 | 2
Branch 1
Port Designation ANT
License Band CEL 900, LNA

Electrical Specifications, Rx Uplink

Frequency Range, MHz 898–915
Bandwidth, MHz 17.00
Gain, nominal, dB 13.0
Gain Tolerance, dB ±1
Noise Figure, maximum, dB 1.8
Noise Figure, typical, dB 1.5
Output IP3, minimum, dBm 23
Return Loss, minimum, dB 18
Insertion Loss - Bypass Mode, typical, dB 2.8
Return Loss - Bypass Mode, typical, dB 18
TX Band Rejection, minimum, dB 80

Electrical Specifications, Tx Downlink

Frequency Range, MHz 943–960
Bandwidth, MHz 17.00
Insertion Loss, maximum, dB 0.60
Return Loss, minimum, dB 18
RX Band Rejection, minimum, dB 70
Input Power, RMS, maximum, W 200
Input Power, PEP, maximum, W 5,000
3rd Order PIM, maximum, dBc -155
3rd Order PIM Test Method Two +43 dBm carriers
5th Order PIM, maximum, dBc -163
5th Order PIM Test Method Two +43 dBm carriers

Material Specifications

Finish Painted

Environmental Specifications

Operating Temperature -40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity Up to 100%
Corrosion Test Method IEC 60068-2-11, 30 days
Ingress Protection Test Method IEC 60529:2001, IP67

Packaging and Weights

Included Mounting hardware
Weight, net 8 kg | 17.637 lb
Click on image to enlarge.
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence

Product Specification

Video

Filter Products – Designed for PIM Excellence
Filter Products – Designed for PIM Excellence